JMS-T2000GC

JMS-T2000GC

High performance gas chromatograph time-of-flight mass spectrometer.

JEM-ARM300F2

JEM-ARM300F2

A new atomic resolution electron microscope has been released! The "GRAND ARM 2" has been upgraded. This new "GRAND ARM 2" enables observations at ultrahigh spatial resolution with highly sensitive analysis over a wide range of accelerating voltages.

JAM-5200 EBM
CRYO ARM 300 II (JEM-3300)

JEM-3300 (CRYO ARM 300 II) Cryo-Electron Microscope

CRYO ARM is an electron microscope for observing biomolecules such as proteins at cryo temperature. The microscope equips a cold field-emission electron gun, an in-column Omega energy filter, a side-entry liquid nitrogen cooling stage, and an automated specimen exchange system. The specimen exchange system can store up to 12 specimens in the specimen exchange chamber.

Electron Microscopy, NMR & Mass Spectometry News

rss

Electron Microscopy News

Our latest blogs on (Scanning) Electron Microscopes, NMR & Mass Spectometry

Visit JEOL at WOTS 2018

WOTS 2018 will be held from October 2nd until October 5th in the Jaarbeurs Utrecht.

JEOL will be present with live SEM demonstrations on our latest model, the JSM-IT200 and we will have our latest Triple Quad Mass Spectrometer on display, the JMS-TQ4000GC.

Of course there will also be plenty of opportunity to discuss with our product specialists to discuss your application and how our instrumentation will help you find your answers. Our booth number is 07E084.

 

JEOL is releasing new triple quadrupole mass spectrometer

JEOL Ltd. (President Gon-emon Kurihara) announces the release of new Gas Chromatograph(GC) -  triple quadrupole mass spectrometer system, JMS-TQ4000GC on August, 2018.

JMS-TQ4000GC is a GC-triple quadrupole mass spectrometer system with both capabilities of high throughput and high sensitivity based on the unique “Short collision cell technology”. Those capabilities can improve the productivity for routine analysis such as residual pesticides analysis in agricultural materials or monitoring of trace amount of chemicals regulated by tap water quality standard and environmental criteria in each region or country.

It is expected that JMS-TQ4000GC would contribute to expand JEOL’s market share of not only GC-triple quadrupole mass spectrometer but also GC-single quadrupole mass spectrometer or GC –time-of-flight mass spectrometer.

[Main Features]

1.   Short collision cell technology enables high speed data acquisition without crosstalk

JMS-TQ4000GC can achieve the fastest SRM (Selected Reaction Monitor) switching speed in the industry at 1,000 channels/sec. Moreover, even at the fast SRM it can eliminate ion interaction among SRM channels (crosstalk) and makes it possible to analyze multi-target compounds with high accuracies.

2.   High sensitivity achieved with ion accumulation and pulsed ion ejection at short collision cell

Short collision cell has both capabilities of ion accumulation and pulsed ion ejection. Noise level of signal can be reduced as much as possible by acquire data only when an ion pulse arrives at the detector. The noise reduction leads to high sensitivity.

3.   Simple operation for data acquisition and analysis with a combination of pre-installed SRM condition file and multi-target quantitative analysis software.

The “peak dependent SRM” system automatically creates the optimized measurement condition when the target pesticides are selected from the pre-installed SRM condition files. After measurement, the multi-target quantitative analysis software “Escrime” analyzes the data and creates the analysis reports according to the report format template selected in advance. In addition, the unique functionalities of “Escrime” such as “Slide show for chromatographic peaks check” and “Across-the-board manual peak integration” make the data verification easier and faster.

[Main Specification]

Measurement modes : Scan, SIM, Scan&SIM, SRM, Product-ion scan, Neutral loss scan, Precursor-ion scan, Scan&SRM

m/z range : 4~1,022

SRM speed : 1,000 channels/sec

Gas Chromatograph JMS-TQ4000GC -  Triple Quadrupole Mass Spectrometer System - JEOL Benelux

JEOL Present at Laborama 2018

JEOL (Europe) BV will be present at the Laborama Expo 2018, on the 15th and 16th of March in the Brussels Kart Expo in Groot Bijgaarden. We will have  our benchtop SEM on display. You are more than welcome to visit us and be informed about our latest developments on SEM, MS and NMR. You can find us at Booth B4. 

For more Information about this event, please visit: http://expo.laborama.be/nl

Announcement Laborama Expo 2018 - Trade Fair for Laboratory Professionals

JEOL introduces the InfiTOF Spectrometer JMS-MT3010HRGA

The InfiTOF  Spectrometer JMS-MT3010HRGA is a Time-of-Flight Mass Spectrometer using Multi-turn® and Perfect focusing® technologies, which achieves high mass-resolving power in a very compact package. This mass spectrometer is designed for real time monitoring of directly introduced gas. It is a high mass-resolution mass spectrometer with stability for real time gas monitoring and capable of elemental composition determination through accurate mass measurement.










High-Resolution Gas Monitoring

MS measurement results shown below are acquired by introducing the standard gases (10 ppm each) and then performing sequential measurement of 4 hours at high mass resolution conditions. High-resolution gas monitoring is enabled for all components over a long period of time with high stability.


High Mass Resolving Power

An innovative Multi-Turn technology makes the spectrometer compact while maintaining high mass resolving power. The maximum resolving power of 40,000 (FWHM) or higher is achieved even for a low-mass range, such as nitrogen molecule (28.0062 Da). With the conventional compact spectrometers, it was difficult to perform mass separation of gas components like carbon monoxide (27.9949) and nitrogen molecule (28.0062), or carbon dioxide (43.9898) and nitrous oxide (44.0011 Da). However, a new InfiTOF can easily separate these gas components and moreover, this revolutionized spectrometer calculates elemental composition through accurate mass measurement. 

Capable of Measuring Hydrogen Ions

JMS-MT3010HRGA is capable of measuring proton (1.0078 Da; a fragment ion of hydrogen molecule) as well as hydrogen molecule (2.0157 Da). Hydrogen is very difficult to measure with a time-of-flight mass spectrometer because of very low mass and fast flight velocity compared to other elements. The JMS-MT3010HRGA, however, achieves stable measurement of these species. This capability will contribute to research of various advanced materials, including electrolytic reactions and catalyst reactions. 


Main Specifications InfiniTOF

  • Mass resolving power 40,000 (FWHM) or higher : m/z 28 of N2
  • Mass range m/z 1 to 1,000
  • Sensitivity S/N ≦10, 38Ar in ambient air (direct infusion through a capillary tube)
  • Mass stability ≦ 100 ppm/h
  • Mass accuracy 3 mDa (Internal standard method) / 5 mDa (External standard merthod)
  • Data acquisition speed Up to 2 GS/s
  • Spectral recording speed Up to 20 spectra/s
  • Dimensions and Weight 430 mm (W) × 625 mm (D) × 552 mm (H) / 40 kgof Main Console (The width of the main console includes the anti-tipping legs.)


JEOL present at WOTS 2016

During WOTS 2016 from October 4th until October 7th in Utrecht, JEOL will be present with live SEM demonstrations and a variety of lectures on the latest developments regarding SEM, TEM, MS and NMR.

Every day presentations will be given in our on-booth lecture room:

Novelties in Liquid and Solids NMR  11:00-11:30

SEM at your fingertips 12:00-12:30

Gas and Volatiles analysis with High resolution MS 14:00-14:30

Introduction to the all-purpose TEM 15:00-15:30

Of course there will also be plenty of opportunity to discuss with our product specialists to discuss your application and how our instrumentation will help you find your answers. Our booth number is 7B034.

See you at WOTS 2016!

JEOL (Europe) BV present at Labtechnology 2015

On the 7th and 8th of October the exhibition Labtechnology 2015 will be held at the Jaarbeurs in Utrecht. JEOL (Europe) BV will be present to promote our recent developments and new products in the field of NMR, Mass spectrometry and Electron Optics. You can find us at booth C18.

To register for this exhibition please visit https://labtechnology.nl/

Logo Exhibition Labtechnology 2015